serv-Clip® Hot Tap Connection

The serv-Clip® tube measuring connection is used to add a test point on an existing hydraulic circuit within 3 minutes—no cutting of pipes, even if the system is pressurized to 9,100 psi (630 bar). Then carry out your measurements: pressure, flow rate, leakage, temperature, oil sampling or connect a variety of measuring devices.

Required tools for installation: allen wrench 6mm and jaw wrench SW22

Models: serv-Clip® Type 1 (Installation on pressurized pipes): Used for sensors with 1/4″ screw

serv-Clip® Type 2 (Installation on non-pressuzied pipes): Used for sensors with 3/8″ screw.

Diameters available :

  • Metric: 10 – 42 mm
  • Tube: 3/8 – 2 inches (9.5 – 50.8mm)
  • Pipe: 1/4 – 3 inches (6.3 – 76.2mm)
  • Over 3 inches (88.9mm) with adaptor SC-XE-607

The flow rate and leakage sensor fluid-Check® functions through the calorimetric principle and can be installed with the serv-Clip tube measuring connection serv-Clip® (type 2) in 5 Minutes without cutting pipelines and while under pressure up to 9,100psi (630bar), from -68 to +176°F (-55 to +80°C). The output signal is 4 to 20mA and is calibrated according to your requirements.

With the Flow Rate Sensor (up to 158 Gallons/minute or 598 Liters/minute):

  • Monitoring flow rate and wear of pumps
  • Operability of accumulators
  • Filter transmittance
  • Heat exchangers
  • Nozzle flow rate
  • Speed of hydraulic motors

With the Leakage sensor (from 0,005283 Gallons/minute):

  •  Seal damage and leakage identification