Hydraulic Pressure Intensifiers – MP-2000-XP Series

The MP-2000-XP pressure intensifier is made for installation in smaller power packs, where a higher end pressure is required, e.g. for a bolt tensioner.  The available ratios of 7:1, 10:1 and 13:1 allows end pressures proportionally of up to 37,700 psi / 2,600 bar to be generated, from a power pack laid out for 200 bar / 2,900 psi max. and a flow rate from 2 to 13 LPM / 0.5 to 3.96 GPM. When the XP-intensifier is connected to P and T, it will automatically increase the supplied pressure proportionally to the required end pressure. For evacuation of the high pressure side a pilot operated check valve is integrated, and when activated, the flow from the high pressure side is led through a separate side port directly to tank, where it will be cooled and filtered before being pumped back in the hydraulic circuit. Below the dimensions and circuit of the intensifier with the oil flow direction is shown.

Ratio Min. Inlet Flow Max. Inlet Flow Outlet Flow Q1 Outlet Flow Q2 Min. Supply Pressure Max. Supply Pressure Max. Output Pressure
(i) (GPM / LPM) (GPM / LPM) (GPM / LPM) (GPM / LPM) (PSI / BAR) (PSI / BAR) (PSI / BAR)
7.0  0.5 / 2 3.4 / 13  0.29 / 1.1  0.05 / 0.2 218 / 15 2,900 / 200 20,300 / 1,400
10.0  0.5 / 2 3.4 / 13  0.18 / .07  0.05 / 0.2  218 / 15 2,900 / 200 29,000 / 2,000
13.0  0.5 / 2 3.4 / 13  0.13 / /05  0.02 / 0.1  218 / 15 2,900 / 200 37,700 / 2,600

Weight: 5.94 lbs / 2.7 KG


Related Products

Pressure Intensifier – How to select

Since, we have decided we want to use a pressure intensifier to get that needed pressure to finish the job […]

read more
Pressure Intensifier – Troubleshooting

Most problems concerning the ScanWill Pressure Intensifiers are caused by the following 7 factors: 1: Contamination of the Fluid If […]

read more
Hydraulic Pressure Intensifiers in High Flow Applications

The MP-Intensifiers have a limitation to the maximum permissible flow supplied to the inlet of the intensifier, which depends on […]

read more